نوع مقاله : مقاله پژوهشی
نویسندگان
1 Mining Engineering Departement, Faculty of Engineering, Universitas Negeri Padang, Indonesia
2 Mining Engineering Departement, Faculty of Engineering, Universitas Negeri Padang, Padang, Indonesia
چکیده
کلیدواژهها
موضوعات
عنوان مقاله [English]
نویسندگان [English]
A lowwall slope failure occurred in the interburden area between Seams B and C of Pit 4 at the PT. Dizamatra Powerindo coal mine during January–February 2026. The failure was associated with high-intensity rainfall and inadequate drainage conditions and was characterized by tension cracks of approximately 100 m in length, ground displacement of 50–100 mm, and surface subsidence of 20–90 cm. This study aims to identify the material parameters controlling the observed slope instability, estimate degraded shear-strength parameters through back-analysis, and evaluate alternative slope geometries using the back-analyzed parameters. Two-dimensional slope stability analyses were conducted using the Morgenstern–Price limit equilibrium method and the Mohr–Coulomb failure criterion. Sensitivity analysis was first performed to identify the controlling material, followed by deterministic and probabilistic back-analysis to estimate the degraded shear-strength parameters under the adopted loading conditions. The initial model yielded a deterministic factor of safety (FoS) of 1.692 and a mean FoS of 1.707. Sensitivity analysis identified sandstone as the material exerting the greatest influence on slope stability. The back-analyzed failure condition resulted in a deterministic FoS of 0.914, a mean FoS of 0.926, and a probability of failure (PoF) of 62.40%. Under this condition, sandstone cohesion decreased from 57.00 to 32.76 kPa, while the internal friction angle decreased from 22.68° to 11.80°, corresponding to reductions of 42.53% and 47.97%, respectively. The back-analyzed parameters were subsequently applied to three alternative slope geometries. The deterministic FoS values for Options 1, 2, and 3 were 1.365, 1.350, and 1.307, respectively, while the corresponding mean FoS values were 1.375, 1.358, and 1.312. All alternatives yielded a PoF of 0.00% and satisfied the adopted minimum FoS criterion of 1.1. Option 3 was selected as the preferred geometry because it provided adequate stability while requiring the smallest cross-sectional cut area. The results demonstrate that sensitivity-guided back-analysis provides a practical basis for estimating degraded material strength and evaluating alternative lowwall geometries following observed slope failure.
کلیدواژهها [English]